We appreciate your interest in the products and services we have to offer at Parts Delivered Today. Part number 500-2 is one of the many Power Supply items tracing back to the manufacturer Ametek Programmable Power Inc which is available for purchase at any time on our database. When you have discovered items of interest, be sure to begin the procurement process by requesting a quote for your comparisons through the submission of an RFQ form. Once our team receives your completed form with your various operational needs and restrictions, we can formulate a solution that suits your specifications within 15 minutes or less.
Note : We Will Not Share Your Information To Any Third Parties.
In addition to products manufactured by Ametek Programmable Power Inc like those with the NSN 6130-01-363-0912 and CAGE Code 25965, we also offer countless other components that you can rely on. For example, items belonging to the FSC 6130 Converters Electrical Non Rotating, among many more, are available for your immediate purchase on our website. In order to ensure the caliber of our offerings, we source all parts from leading global manufacturers that are on our Approved Vendors List (AVL). Moreover, countless products are subjected to rigorous quality assurance measures to guarantee their fit, form, and function prior to shipment. Through our numerous dedications and practices, we are proud to serve as an AS9120B, ISO 9001:2015, and FAA AC 00-56B accredited distributor. To learn more about our services and products, we encourage you to call or email us at any time; a representative will be more than happy to assist you however we can throughout the procurement process.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6130-01-363-0912 Item PartTypeName: POWER SUPPLY | 6130 | 013630912 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
500-2 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
APNX | INPUT VOLTAGE RATING | 115.0 AC POUNDS PER HOUR WET 1ST ALTERNATE OPERATING POWER RQMT |
APTS | OUTPUT FREQUENCY RATING | 45.0 HERTZ MINIMUM 3RD POWER OUTPUT AND 5.0 KILOHERTZ MAXIMUM 3RD POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 0.0 AC AMPERES MINIMUM 1ST POWER OUTPUT AND 9.2 AC AMPERES MAXIMUM 1ST POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 0.0 AC AMPERES MINIMUM 2ND POWER OUTPUT AND 2.25 AC AMPERES MAXIMUM 2ND POWER OUTPUT |
CWGH | OUTPUT CURRENT RATING | 0.0 AC AMPERES MINIMUM 3RD POWER OUTPUT AND 1.1 AC AMPERES MAXIMUM 3RD POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 1 1ST POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP 2ND POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP 3RD POWER OUTPUT |
CWHM | INPUT CURRENT RATING | 1500.0 AC AMPERES NOMINAL 1ST ALTERNATE OPERATING POWER RQMT |
CWHQ | INPUT CONNECTION TYPE | TERMINAL STRIP 2ND ALTERNATE OPERATING POWER RQMT |
ABKW | OVERALL HEIGHT | 5.250 INCHES NOMINAL |
AKWC | ELECTRICAL POWER SOURCE RELATIONSHIP | OPERATING |
APPA | OUTPUT VOLTAGE RATING | 0.0 AC VOLTS MINIMUM 2ND POWER OUTPUT AND 130.0 AC VOLTS MAXIMUM 2ND POWER OUTPUT |
APPA | OUTPUT VOLTAGE RATING | 0.0 AC VOLTS MINIMUM 3RD POWER OUTPUT AND 260.0 AC VOLTS MAXIMUM 3RD POWER OUTPUT |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM 1ST ALTERNATE OPERATING POWER RQMT AND 63.0 HERTZ MAXIMUM 1ST ALTERNATE OPERATING POWER RQMT |
CWHC | OUTPUT CONTROL LOCATION | REAR PANEL 2ND POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 1 2ND POWER OUTPUT |
CWHQ | INPUT CONNECTION TYPE | TERMINAL STRIP 1ST ALTERNATE OPERATING POWER RQMT |
CWHT | INPUT CONNECTION QUANTITY | 1 2ND ALTERNATE OPERATING POWER RQMT |
ANPM | INPUT PHASE | SINGLE 2ND ALTERNATE OPERATING POWER RQMT |
APPA | OUTPUT VOLTAGE RATING | 0.0 AC VOLTS MINIMUM 1ST POWER OUTPUT AND 32.0 AC VOLTS MAXIMUM 1ST POWER OUTPUT |
APTQ | INPUT FREQUENCY RATING | 47.0 HERTZ MINIMUM 2ND ALTERNATE OPERATING POWER RQMT AND 63.0 HERTZ MAXIMUM 2ND ALTERNATE OPERATING POWER RQMT |
APTS | OUTPUT FREQUENCY RATING | 45.0 HERTZ MINIMUM 1ST POWER OUTPUT AND 5.0 KILOHERTZ MAXIMUM 1ST POWER OUTPUT |
CBBL | FEATURES PROVIDED | PROGRAMMABLE AND OVER TEMPERATURE PROTECTION AND OVER VOLTAGE PROTECTOR |
CWGN | OUTPUT PHASE | TWO 2ND POWER OUTPUT |
CWHC | OUTPUT CONTROL LOCATION | REAR PANEL 1ST POWER OUTPUT |
CWHJ | OUTPUT CONNECTION TYPE | TERMINAL STRIP 1ST POWER OUTPUT |
CWHT | INPUT CONNECTION QUANTITY | 1 1ST ALTERNATE OPERATING POWER RQMT |
ABHP | OVERALL LENGTH | 19.000 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 16.000 INCHES NOMINAL |
AGAV | END ITEM IDENTIFICATION | F110 ACFT/GE100 ENG |
ANPM | INPUT PHASE | SINGLE 1ST ALTERNATE OPERATING POWER RQMT |
APNX | INPUT VOLTAGE RATING | 230.0 AC POUNDS PER HOUR WET 2ND ALTERNATE OPERATING POWER RQMT |
APTS | OUTPUT FREQUENCY RATING | 45.0 HERTZ MINIMUM 2ND POWER OUTPUT AND 5.0 KILOHERTZ MAXIMUM 2ND POWER OUTPUT |
AYNH | OPERATING AMBIENT TEMP RANGE | 0.1/50.0 DEG CELSIUS |
CWGN | OUTPUT PHASE | TWO 1ST POWER OUTPUT |
CWGN | OUTPUT PHASE | TWO 3RD POWER OUTPUT |
CWHC | OUTPUT CONTROL LOCATION | REAR PANEL 3RD POWER OUTPUT |
CWHF | OUTPUT CONNECTION QUANTITY | 1 3RD POWER OUTPUT |
CWHM | INPUT CURRENT RATING | 1500.0 AC AMPERES NOMINAL 2ND ALTERNATE OPERATING POWER RQMT |
FEAT | SPECIAL FEATURES | CONSIST OF:2 EA MODEL 251B;1 EA 400SR AND 1 EA 990-302-92 CABLE PLUS ASELECTED OSCILLATOR |