We appreciate your interest in the products and services we have to offer at Parts Delivered Today. Part number 04306-3004 is one of the many Meter Electrical Fr items tracing back to the manufacturer Ideal Precision Meter Co which is available for purchase at any time on our database. When you have discovered items of interest, be sure to begin the procurement process by requesting a quote for your comparisons through the submission of an RFQ form. Once our team receives your completed form with your various operational needs and restrictions, we can formulate a solution that suits your specifications within 15 minutes or less.
Note : We Will Not Share Your Information To Any Third Parties.
In addition to products manufactured by Ideal Precision Meter Co like those with the NSN 6625-00-004-8066 and CAGE Code 11707, we also offer countless other components that you can rely on. For example, items belonging to the FSC 6625 Electrical and Electronic Properties Measuring and Testing Instruments, among many more, are available for your immediate purchase on our website. In order to ensure the caliber of our offerings, we source all parts from leading global manufacturers that are on our Approved Vendors List (AVL). Moreover, countless products are subjected to rigorous quality assurance measures to guarantee their fit, form, and function prior to shipment. Through our numerous dedications and practices, we are proud to serve as an AS9120B, ISO 9001:2015, and FAA AC 00-56B accredited distributor. To learn more about our services and products, we encourage you to call or email us at any time; a representative will be more than happy to assist you however we can throughout the procurement process.
MRC | Criteria | Characteristic |
---|---|---|
AFFL | Mounting Bolt Circle Diameter | 3.160 INCHES NOMINAL |
AMQY | Installation Design | PANEL |
ABHP | Overall Length | 2.060 INCHES NOMINAL |
APST | Meter Depth Behind Mounting Flange | 1.660 INCHES NOMINAL |
NHCF | Nuclear Hardness Critical Feature | HARDENED |
APSW | Meter Body Diameter Behind Mounting Flange | 2.800 INCHES NOMINAL |
STYL | Style Designator | ROUND FLUSH MTG |
ADAV | Overall Diameter | 3.510 INCHES NOMINAL |
MRC | Decoded Requirement | Clear Text Reply |
BLSB | Scale Selection Method | TERMINAL |
ADAG | Mounting Stud Length | 0.375 INCHES MINIMUM AND 0.625 INCHES MAXIMUM |
CTTD | Circuit Attachment Method And Quantity | 2 THREADED STUD |
AQFY | Background Color | WHITE SINGLE INDICATOR SINGLE RANGE |
CBBL | Features Provided | ZERO ADJUSTER |
AXHR | Mounting Facility Type And Quantity | 3 UNTHREADED HOLE |
ABTB | Mounting Hole Diameter | 0.143 INCHES MINIMUM AND 0.157 INCHES MAXIMUM |
FEAT | Special Features | TERMINAL NO. 1/4-28 IN. THD 0.620 IN. LG |
ANRL | Mounting Arrangement Style | THREE HOLE/STUD BOLT CIRCLE |
BHMW | Measurement Range | +0.0 TO 133.0 VOLTS, AC SINGLE INDICATOR 1ST RANGE |
APMM | Dial Scale Marking Color | BLACK SINGLE INDICATOR SINGLE RANGE |
BHMW | Measurement Range | +0.0 TO 160.0 VOLTS, AC SINGLE INDICATOR 2ND RANGE |
AACT | Circuit Current For Which Designed | DC |
AMKD | Indicator Type | DIAL W/POINTER |
MARK | Special Markings | PERCENT RATED CURRENT,DOUBLE WIDTH RED LINE AT 0.75 AMPS FOR 60 HZSCALE,DOUBLE WIDTH BLUE LINE AT 0.625 AMPS FOR 50 HZ SCALE |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”.
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote